Crack formation on resected root surfaces subjected to conventional, ultrasonic, and laser root-end cavity preparation

Aydemir, S.
Journal of Endodontics, 2014;40(4), pp.584–587.

Objective: 

The aim of this study was to evaluate cracks on root ends following resection and cavity preparation with a laser and two established techniques.

Background data:

 If root canal treatment of a tooth fails, an apicoectomy operation may be indicated. Three millimeters of the root tip is resected and a cavity of similar depth with parallel walls is cut to receive a root-end filling.

Materials and methods: 

Sixty extracted human maxillary anterior teeth were used. Their root canals were prepared with rotary instruments, and they were filled with gutta-percha. Twenty teeth were resected with tungsten carbide fissure burs, and their root-end cavities cut with tungsten carbide round burs at a slow speed (Group 1). The other 40 teeth were resected with an Er:YAG laser, and root-end cavities were made with the same laser (Group 2), or with an ultrasonically-powered zirconium nitride coated retrotip (Group 3). The number and types of cracks on the resected surfaces were assessed using a stereomicroscope before and after cavity preparation.

Results: 

Cracking was not significantly different between the more conventional group and the laser groups after resections (p>0.05) or following cavity preparation (p>0.05).

Conclusions:

 In this in vitro study, the laser resection and root-end preparation technique did not influence the number or type of cracks formed on the root surfaces.